W21-plus
With 12.5 cm mesh MINI-plusWith sealing lip and 12.5 cm mesh

Die APU-Window reveal bead with mesh MINI-plus W21-plus

The APU window reveal bead with mesh MINI-plus is used in external thermal insulation composite systems (ETICS) in accordance with the APU application range. Within the reveal the profile is stuck flush to the structural element there and thus forms a clean and reliable termination of the plaster with sealing lip.

The profile comes with a self-adhesive PE foam tape, which ensures a watertight, lasting seal. A TPE sealing lip protects the PE foam tape and forms a visually clean joint with the adjacent building component. A fabric strip is welded to the profile. Each bar has a fabric overhang on one side of 10 cm in the lengthways direction There is a piece of self-adhesive tape on protective flap in order to secure the third-party protective film. This protects the window during the plastering work. After completion of these tasks, the protective flap is pulled off and what is created is a clean edge to the plaster.

Area of application W20 MINI-plus

With adhesive connection – only for surfaces suitable for being stuck to
Test of adhesion required

Window position
Within masonry
Insulating material thicknessup tp 160mm
Window sizeup tp 2.6m²

Design

Window reveal bead with mesh MINI-plus, With sealing lip and 12.5 cm mesh
W21-24PLUS
Length2.4 m
Packaging unit25 bars = 60 m
Weight (per PU)6.7 kg

Features

 
Material
  • Material Rigid PVC, manufactured in accordance with DIN 16941
  • TPE, manufactured in accordance with DIN 16941
Protective flap
  • Removable flap with soft TPE joint and double-sided adhesive tape
Seal
  • PE foam tape 8 x 3 mm
Mesh
  • Min. 160 g/m2, approved for use in ETICS
  • 12.5 cm wide, mesh size 4 x 4 mm
  • ultrasonically welded

Important notes

StorageAlways store profiles laid down in a dry place.
UseCan be used only on white plastic windows.
Test of adhesionPerform adhesion test.
Other applicationsAny applications not clearly described in the documents may be implemented only after consultation with the plaster or ETICS manufacturer.

Details

Sectional drawing in mm

 

Application drawing

Your watchlist is empty